- 01 Description of Password Programming Function
- 02 Setting method of the main password
- 03 Password and RFID card open and close
- 04 Password cancellation function
- 05 Locking function
- 06 Micro-power consumption function
- 07 Emergency start
- 08 Battery energy detection
- 09 Error message is prompted
- 10 CEU sets the safe room number
- 11 Query the system information
Description of Password Programming Function
Open the safe with the initial password 1234, and when the door is open:
Enter the “*” “*” keys, and the screen will display “PROG”. Enter the function code “751019”, and now the operation screen will start to change into the programming code of the safe. There is a screen of programming codes, and the following is the description of these programming codes:
The first screen: The default parameters are: 141301
Position:
(1) Password display bit:
Hit 0 - Do not display the personal password entered each time, with a sound prompt.
Hit 1 - Display the personal password entered each time, with a sound prompt.
Hit 2 - Display the personal password entered each time, without echoing the password, with a sound prompt.Hit 3 - Do not display the personal password entered each time, without a sound prompt.
Hit 4 - Display the personal password entered each time, echoing the password, without a sound prompt.
(2) Password digit setting bit
Hit 4 - Set a 4-digit password
Hit 5 - The setting of a 5-digit password
Hit 6 - Set a 6-digit password
Hit 7 - Set a 4 - 6-digit password
(3) Setting of lock time after N errors
Hit 0 – Lock for 0 minutes after 4 errors
Hit 1 - Lock for 15 minutes after 4 errors
Hit 2 - Lock for 30 minutes after 4 errors
Hit 3 - Lock for 15 minutes after 3 errors
Hit 4 - Lock for 30 minutes after 3 errors
(4) Master password setting bit
Hit 2 - The master password is not used Voltage display in 6 levels
Hit 3 - The master password is used Voltage display in 6 levels
Hit 6 - The master password is not used Voltage display in 2 levels
Hit 7 - The master password is used Voltage display in 2 levels
⑸ Record information setting bit
Click 0-record the door opening information, and the low voltage can be closed.
Click 1-Record the opening and closing information, low voltage can be closed.
Click 2-Record the door opening information, low voltage can not close the door.
Click 3-Record the open and closing information, low voltage can not close.
⑹ Working mode setting
Click the 0 of the user to enter the personal password, and then press the lock key # to close the door. The safe will save the last closing password. Press the "#" key to close the door next time.
Change password: When the door is open, enter "* * 6 8 #" to display "NEW". Reset a new set of personal passwords, enter a new set of new passwords and press #, then the door lock is closed, and then the new password is displayed. Press the first key after hibernation will read the key value
Click 1-The user enters the personal password, and then press the lock key # to close the door. A new password has been set up when the door is open. This method is especially suitable for use in hotels. Press the first key after hibernation will read the key value
Click 2-sleep after pressing the first key will not read the key value, other the same as 0.
Click 3-pressing the first key will not read the key value, the same as 1.
After pressing confirmation key #, if the parameters are set correctly, the system will exit programming mode; if entering a value outside the specified number, the screen displays "ERROR" and stored as the default value 141301.
Setting method of the main password
(1)Enter "*" "*", the screen will show "PROG", enter 1967, the screen will show "NEW".
(2)Within 5 seconds after the "NEW" disappears, enter your favorite password (6 digits), and the screen will display "AGAIN".
(3)Within 5 seconds after the AGAIN disappears, enter the new password again, and the screen will show "DONE", indicating that the new main password has been set successfully.
(4)If you want to change the main password again, follow the original steps.
Note: The new main password should not be set to the function code (e. g., 751019,621223, etc.) to avoid confusion. The main password is preset to the initial value of 800109.
Password and RFID card open and close
Personal mode:
(1)Enter a four-digit password (it can be a five-digit or six-digit password, determined by the programming control bit).
(2)Press OK #, while the display displays "CLOSE-" and the power door starts. The display displays "CLOSED" after the latch closes smoothly.
(3)Enter the password set when locking the door, and the display displays "-OPEN-" when the electric latch starts. After the latch opens smoothly, the display displays "OPENED", indicating that the safe door can now be opened.
In this mode, close the door again
Change password: When the door is open, enter "* * 6 8 #" to display "NEW". The old personal password has been cleared, and a new set of personal passwords should be reset.
Hotel mode:
(1)Enter a four-digit password (it can be a five-or six-digit password, determined by the programming control bit).
(2)Press OK #, while the display displays "CLOSE-", the electric door starts, and the display displays "CLOSED" after the latch closes smoothly.
(3)Enter the password set when locking the door, the display shows "-OPEN-" and the electric latch start. After the latch is successfully opened, the "OPENED" on the display can now open the safe door
Change the password: when the door is open (the latch is in the unlocked position), the password can be changed at any time when closing
swing card:
Only one guest code can be set. After opening the door with the RFID card, the last password will be invalid; otherwise, after the opening, the card number of the original RFID card will also be invalid.
Password cancellation function
When not wanting to display the input password on the display screen, you can modify the programming control bit setting. When the first bit of the programming code is set to 0, the cancellation function can be activated (only "-" is displayed on each input screen). If you need to restore the display, the first bit of the programming code must be set to 1 again, and the cancellation function can be cancelled.
Note: This feature is suitable for users who need permanent extinction.
Hot key function: input "0 #" key-extinction function is activated, only "-" is displayed on each input screen.
Enter "9 #" key-the cancellation function is cancelled and the screen will restore the digital display status.
Note: The extinction function activated by hot key mode can only be used as the extinction of the current operation, and the screen will restore the digital display status in the next operation.
Locking function
Enter the wrong password for four times, the system will automatically lock, and then press the keyboard to appear "HOLD15" must wait for 15 minutes before the system will automatically open, allowing the keyboard input (modify the third bit of the programming code for 0 minutes or 30 minutes).
Micro-power consumption function
The system quickly into the state of micro-power consumption, can save power consumption, prolong the service life of the battery.
Emergency start
When the password is forgotten or the built-in battery is exhausted, use the mechanical emergency key to open the door.
Battery energy detection
Press OK # to enter the battery energy detection program. There are "BA-LO" ~ "BA-HI". If "BA-HI" on the display means that the battery is sufficient, "BA-LO" means that the battery is low, and the battery needs to be replaced as soon as possible.
Error message is prompted
When the following prompts appear on the display screen, please follow the following instructions:
ERROR:
1. If the password is wrong, you need to enter the password correctly;
2. Incorrect input parameters;
3. The parameter setting is long with no input. Please enter the parameter setting page for setting.
ERROR1-Push the latch by hand. Move the door panel to let the latch loose and then open the door again.
ERROR2-It means that the latch head is blocked (maybe the door will be ajar) and cannot complete the lock, please push the door panel, push the door solid, and then close the door again.
CEU sets the safe room number
Connect the CEU to the USB communication interface of the safe. Click the clear key "*" of CEU for 2 times, the screen will display "PROG", input the function code 7510 * 6, the screen shows "NO" display disappeared, enter the 4-bit room number, press # key to confirm, the screen shows "done", the safe shows the set room number, indicating the room number set successfully.
Query the system information
Press "* * 46 #", the display screen pops up the room number of the safe.
Press "* * 36 #", the display pop up the version number of the safe electronic system.
Press "* * 56 #" for the system time of the safe.
Press "* * 81 #", the display screen popup CARD ON, indicating that the card swiping function is enabled.
Press "* * 80 #", the display screen pop up CARD OFF, indicating that the card function is off.