Description of Password Programming Function
Open the safe with the initial password 1234, and when the door is open:
Enter the “*” “*” keys, and the screen will display “PROG”. Enter the function code “751019”, and now the operation screen will start to change into the programming code of the safe. There is a screen of programming codes, and the following is the description of these programming codes:
The first screen: The default parameters are: 141301
Position:
(1) Password display bit:
Hit 0 - Do not display the personal password entered each time, with a sound prompt.
Hit 1 - Display the personal password entered each time, with a sound prompt.
Hit 2 - Display the personal password entered each time, without echoing the password, with a sound prompt.Hit 3 - Do not display the personal password entered each time, without a sound prompt.
Hit 4 - Display the personal password entered each time, echoing the password, without a sound prompt.(2) Password digit setting bit
Hit 4 - Set a 4-digit password
Hit 5 - The setting of a 5-digit password
Hit 6 - Set a 6-digit password
Hit 7 - Set a 4 - 6-digit password
(3) Setting of lock time after four errors
Hit 0 - Lock for 0 minutes
Hit 1 - Lock for 15 minutes
Hit 2 - Lock for 30 minutes
(4) Master password setting bit
Hit 2 - The master password is not used Voltage display in 6 levels
Hit 3 - The master password is used Voltage display in 6 levels
Hit 6 - The master password is not used Voltage display in 2 levels
Hit 7 - The master password is used Voltage display in 2 levels
(5) Record information setting bit
Hit 0 - Record the door opening information, and the low voltage can close the door.
Hit 1 - Record the door opening and closing information, and the low voltage can close the door.
Hit 2 - Record the door opening information, and the low voltage cannot close the 门.
Hit 3 - Record the door opening and closing information, and the low voltage cannot close the door.
(6) Working mode setting
Hit 0 – The user enters the personal password and then presses the lock key # to close the door. The safe will save the last closing password. Next time, just press the “#” key to close the door.
To change the password: When the door is opened, enter “* * 6 8 #” and “NEW” will be displayed. A new set of personal passwords needs to be reset. Enter a new password and press #. At this time, the door lock closes and the new password is displayed.
Hit 1 - The user enters the personal password and then presses the lock key # to close the door. A new password can be set when the door is opened. This mode is especially suitable for hotel use.
After pressing the confirmation key #, if the parameters are to be set correctly, the system will exit the programming mode; if a value other than the specified number is entered, the screen will display “ERROR” and store the default value 141301.
Method of setting the master password
(1)Enter the “*” “*” keys, and the screen will display “PROG”. Enter 1967, and the screen will display “NEW”.
(2)Within 5 seconds after “NEW” disappears, enter the password you like (6 digits), and the screen will display “AGAIN”.
(3)Within 5 seconds after “AGAIN” disappears, repeat the new password again, and the screen will display “DONE”, indicating that the new master password has been set successfully.
(4)If you want to change the master password again, just follow the original steps.
Note: Do not set the new master password as the function code (for example: 751019, 621223, etc.), to avoid confusion. The master password is preset to the initial value 800109 at the factory.
Enter the password to open and close the door
Personal mode:
(1)Enter a four-digit password (it can be a five-digit or six-digit password, determined by the programming control bit).
(2)Press OK #, while the display displays "CLOSE-" and the power door starts. The display displays "CLOSED" after the latch closes smoothly.
(3)Enter the password set when locking the door, and the display displays "-OPEN-" when the electric latch starts. After the latch opens smoothly, the display displays "OPENED", indicating that the safe door can now be opened.
In this mode, close the door again
Change password: When the door is open, enter "* * 6 8 #" to display "NEW". The old personal password has been cleared, and a new set of personal passwords should be reset
Hotel mode:
(1)Enter a four-digit password (it can be a five-digit or six-digit password, determined by the programming control bit).
(2)Press OK #, while the display displays "CLOSE-", the electric door starts, and the display displays "CLOSED" after the latch closes smoothly.
(3)Enter the password set when locking the door, the display shows "-OPEN-" the electric latch to start, after the latch is successfully opened, the "OPENED" on the display can now open the safe door
Change the password: when the door is open (the latch is in the unlocked position), the password can be changed at any time when closing
Password cancellation function
When not wanting to display the input password on the display screen, you can modify the programming control bit setting. When the first bit of the programming code is set to 0, the cancellation function can be activated (only "-" is displayed on each input screen). If you need to restore the display, the first bit of the programming code must be set to 1 again, and the cancellation function can be cancelled.
Note: This feature is suitable for users who need permanent extinction.
Hot key function: input "0 #" key-extinction function is activated, only "-" is displayed on each input screen.
Enter "9 #" key-the cancellation function is cancelled and the screen will restore the digital display status.
Note: The extinction function activated by hot key mode can only be used as the extinction of the current operation, and the screen will restore the digital display status in the next operation.
Locking function
Enter the wrong password for four times, the system will automatically lock, and then press the keyboard to appear "HOLD15" must wait for 15 minutes before the system will automatically open, allowing the keyboard input (modify the third bit of the programming code for 0 minutes or 30 minutes).
Micro-power consumption function
The system quickly into the state of micro-power consumption, can save power consumption, prolong the service life of the battery.
Emergency start
When the password is forgotten or the built-in battery is exhausted, use the mechanical emergency key to open the door.
Battery energy detection
Press OK # to enter the battery energy detection program. There are "BA-LO" ~ "BA-HI". If "BA-HI" on the display means that the battery is sufficient, "BA-LO" means that the battery is low, and the battery needs to be replaced as soon as possible.
Error message is prompted
When the following prompts appear on the display screen, please follow the following instructions:
ERROR:
1. If the password is wrong, you need to enter the password correctly;
2. Incorrect input parameters;
3. The parameter setting is long with no input. Please enter the parameter setting page for setting.
ERROR1-Push the latch by hand. Move the door panel to let the latch loose and then open the door again.
ERROR2-It means that the latch head is blocked (maybe the door will be ajar) and cannot complete the lock, please push the door panel, push the door solid, and then close the door again.
CEU sets the safe room number
Connect the CEU to the USB communication interface of the safe. Click the clear key "*" of CEU for 2 times, the screen will display "PROG", input the function code 7510 * 6, the screen shows "NO" display disappeared, enter the 4-bit room number, press # key to confirm, the screen shows "done", the safe shows the set room number, indicating the room number set successfully.
Query the system information
Press "46 #" and the screen displays the room number of the safe.
Press "36 #", the version number of the safe electronic system.